Industries

Electric motors of smoke exhausters and fans

Electric motors of smoke exhausters and fans

Smoke exhausters and draft machines provide draft in boiler houses, furnaces and industries. Their engines operate at high temperatures and require precise balancing. Let's look at the specifics of smoke exhaust engines.

Operating features

  • High temperatureof the pumped gases and medium.
  • Continuous modeof operation.
  • Large rotating masses - balancing is critical.
  • Vibration loads.

Main the task is balancing

An imbalance of the smoke exhauster rotor causes strong vibration, which destroys the bearings and foundation. Therefore, rotor balancing is a key operation in the repair and maintenance of such machines.

Typical faults

ProblemCause
Strong vibrationImbalance, sticking to impeller
Bearing wearVibration, temperature
Winding overheatingHigh ambient temperature

Repair

For smoke exhaust engines, heat-resistant insulation and mandatory balancing after repair are important. If the winding is damaged - rewind with heat-resistant materials. Regular vibration diagnostics prevents accidents.

Do you need repair and balancing of a smoke exhauster engine in Tashkent? Elektromotors engineers will eliminate vibration - leave a request.

Need specialist help?

Contact Elektromotors engineers — we will help diagnose and repair your electric motor.

+998 94 680 15 04 Contact us